Implementation of and Electrical Bioimpedance Measurement System for Renal Function Monitoring
Högskolan i Borås, Institutionen Ingenjörshögskolan.
2008 (Engelska)Självständigt arbete på avancerad nivå (magisterexamen)Studentuppsats (Examensarbete)
Abstract [en]

Peritoneal Dialysis is a treatment for patients suffering from renal failure that allows out-patient care. This means that the patient only needs to visit the hospital for consultation and not for treatment, increasing considerably the comfort of the patient, while reducing remarkably the cost per patient. In order to increase the level of medical supervision obtained with the periodic visits to the clinic, televisit has been put into practice in some hospitals. But these televisits are based on indirect and qualitative indicators of renal failure, and therefore they are just valid for detection of situations near limit cases, such as well over-hydrated or dehydrated. Electrical Bioimpedance Measurements have been proved to constitute an appropriate method for assessment of body composition, and therefore they can provide with direct indicators of body fluid distribution. Such ability of EBI technology allows the detection of body fluid unbalance caused by renal dysfunction, and therefore, nephrology televisits would benefit tremendously from EBI measurements. This project is based on the AD5933 Impedance Network Analyzer of Analog Devices, and the main task is to develop a software application that controls the evaluation board in which it is implemented, and allows the storage of the EBI measurements in EDF+ files that will facilitate the management of medical data when applied to televisit. These files are uploaded to XML format in order to be sent to a remote server, where a software application will have been implemented for medical consultation.

Ort, förlag, år, upplaga, sidor
University of Borås/School of Engineering , 2008.
Serie
Magisteruppsats
Nyckelord [en]
electrical bioimpedance, renal failure, peritoneal dialysis, 4-electrode method, portable, telemedicine, home healthcare
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:hb:diva-18839Lokalt ID: 2320/3650OAI: oai:DiVA.org:hb-18839DiVA, id: diva2:1310773
Anmärkning
Uppsatsnivå: DTillgänglig från: 2019-04-30 Skapad: 2019-04-30 Senast uppdaterad: 2025-09-24

Open Access i DiVA

fulltext(2854 kB)471 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2854 kBChecksumma SHA-512
84efc601da2029d605daa85dbfc5e7fb51f06758fdfe2c83b6eaddfb7a22a04c8654a1167d438052052f0492010ebea90fc65b29d3758e79b9249389f98de572
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen Ingenjörshögskolan
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 472 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 239 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf