Textile Sensor Using Piezoelectric Fibers for Measuring Dynamic Compression in a Bowel Stent
Högskolan i Borås, Institutionen Textilhögskolan.
2014 (Engelska)Självständigt arbete på avancerad nivå (masterexamen)Studentuppsats (Examensarbete)
Abstract [en]

In this experimental study the in-lined poled piezoelectric poly(vinylidene fluoride)(PVDF) bicomponent fiber was investigated the suitability in applications within the area of textile sensors when used in a bowel stent. Today there are only piezoelectric films made of PVDF available. Compared to a film, a fiber increases the amounts of application abilities. In this study a plain weave, resembling a coordinate system was made of the piezoelectric PVDF fiber and tested on top of two different beds; one hard and one elastic made of foam. The structure was then developed into two structures; one integrated in the stents structure with a plain weave pattern and one secondary structure as a plain weave placed onto the stent. Two test methods were developed in order to resemble the bowel movements to test the two piezoelectric PVDF fiber based structures. A reliability test in a reometer was made of the fiber, giving high differences in mean values. An in vivo test was conducted in a pig where the stent was placed in the orifice of the stomach. Both structures shown response when both developed methods was used. Due to large irregularities within the piezoelectric PVDF fiber the evaluation between the two structures was not possible. The most favorable structure was the secondary structure due to the larger continuous process ability and application areas. It was also seen that the reliability of the piezoelectric PVDF fiber is low, giving a non-reliable sensor.

Ort, förlag, år, upplaga, sidor
University of Borås/Swedish School of Textiles , 2014.
Serie
Masteruppsats ; 2014.14.02
Nyckelord [en]
Piezoelectricity, advanced textile structure, textile sensor, piezoelectric poly(vinylidene fluoride, )(PVDF), textile medical device, self-sensing stent
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:hb:diva-17999Lokalt ID: 2320/14064OAI: oai:DiVA.org:hb-17999DiVA, id: diva2:1309912
Anmärkning
Program: TextilteknikTillgänglig från: 2019-04-30 Skapad: 2019-04-30 Senast uppdaterad: 2025-09-24

Open Access i DiVA

fulltext(3112 kB)515 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3112 kBChecksumma SHA-512
9f1882be758dfba0470afd94170254de2c7cae4340ea9aee3307e11db6ae110256d86fa255be34b4a7819cdef35c72555ad87759185cfb50db675432a41b8834
Typ fulltextMimetyp application/pdf

Av organisationen
Institutionen Textilhögskolan
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 515 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 460 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf