On the Feasibility of Using Textile Electrodes for Electrical Bioimpedance Measurements
Högskolan i Borås, Institutionen Ingenjörshögskolan. (Medical TexTTronics)
2011 (engelsk)Licentiatavhandling, monografi (Annet vitenskapelig)
Abstract [en]

The application of textile electrodes has been widely studied for biopotential recordings, especially for monitoring cardiac activity. Commercially available applications, such as the Adistar T-shirt and the Numetrex Cardioshirt, have shown good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for electrical bioimpedance (EBI) spectroscopy measurements in home and personalized health monitoring applications, however solid basic research about the measurement performance of the electrodes must be performed prior to the development of any textile-enabled EBI application. This research work studies the performance of EBI spectroscopy measurements when performed with textile electrodes. An analysis using an electrical circuit equivalent model and experimental data obtained with the Impedimed spectrometer SFB7 was carried out. The experimental study focused on EBI spectroscopy measurements obtained with different types of textile electrodes and in different measurement scenarios. The equivalent model analysis focused on the influence of the electrode polarization impedance Zep on the EBI spectroscopy measurements in the frequency range of 3 kHz to 500 kHz. The analysis of the obtained complex EBI spectra shows that the measurements obtained with textile electrodes produce constant and reliable EBI spectra. The results also indicate the importance of the skin-electrode interface in EBI spectroscopy measurement. Textile technology, if successfully integrated, may enable the performance of EBI spectroscopy measurements in new scenarios, which would allow the generation of novel, wearable, or textile-enabled applications for home and personal health monitoring

sted, utgiver, år, opplag, sider
Stockholm :Skolan för teknik och hälsa, Kungliga Tekniska högskolan , 2011.
Serie
TRITA-STH : report, ISSN 1653-3836 ; 2011:1
Emneord [en]
textile electrodes, bioimpedance, Textile & Medical Electronics
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-3607Lokal ID: 2320/10115ISBN: 978-91-7415-857-1 (tryckt)OAI: oai:DiVA.org:hb-3607DiVA, id: diva2:876997
Merknad

Thesis Supervisors: Kaj Lindecrantz and Fernando Seoane

Sponsorship:

Mexican CONACYT

Tilgjengelig fra: 2015-12-04 Laget: 2015-12-04 Sist oppdatert: 2025-09-24

Open Access i DiVA

fulltekst(3543 kB)2390 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3543 kBChecksum SHA-512
f99fd97da5e90edd05c17e14bd8d2c060f371c46a28934542a58253b9e48d306927e209f5c5d76e710610c6b31e4e025da154f564b418f5b90a6d34791bd0828
Type fulltextMimetype application/pdf

Person

Marquez, Juan Carlos

Søk i DiVA

Av forfatter/redaktør
Marquez, Juan Carlos
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 2395 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 786 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf