Prästgårdsliden Hökerum: En systemutredning för värme- och luftbehandlingssytem
University of Borås, Faculty of Textiles, Engineering and Business.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Prästgårdsliden Hökerum : An inquiry of systems for heat and ventilation (English)
Abstract [sv]

Syftet med studien är att utför en systemutredning med avseende på värme- och luftbehandlingssystem för en aktuell byggnad. Studien fokuserar på att utreda vilka system som är mest optimala för fastigheten. För att lyckas med det utförs en komparativ studie där olika utvalda systemförslag jämförs för att undersöka vilka system som ger den mest energi- och kostnadseffektiva installationen. I rapporten presenteras även en teknikstudie som ska ge den grundläggande kunskap som anses krävas för utredningen. I studien används handberäkningar med gradtimmar och beräkningsprogrammet VIP-Energy för att beräkna byggnadens energi- och effektbehov. Dessutom erhålls information om de olika systemen genom regelbunden kontakt med leverantörer. För luftbehandling handlar studien om att undersöka om ett centralt FTX-aggregat eller lägenhetsaggregat är mest gynnsamt för byggnaden. Utredningen av värmesystemet avser att jämföra bergvärmepumpar mot luft/vatten-värmepumpar för att uppnå ett kostnadseffektivt system. Jämförelsen av systemen utförs genom att ställa för- och nackdelar samt lönsamhetskalkyler mot varandra. På så sätt kan de mest lönsamma systemen för värme- och luftbehandling presenteras. Studien resulterar i att byggnadens energibehov är 69 575 kWh enligt VIP-Energy. Effektbehovet beräknas med hjälp av handberäkningar och resulterar i 25 kW. För luftbehandlingssystemet resulterar undersökningen i att lägenhetsaggregat är den bästa lösningen. Det aggregat som anses vara mest lämpad är Swegon R2 Comfort med roterande värmeväxlare. Den värmepump som ger den mest kostnadseffektiva installationen är CTC EcoPart 414 med en märkeffekt på 14 kW.

Abstract [en]

The purpose of this study is to do an inquiry of systems for heat and ventilation for a current building. The focus of the study is to investigate which system that is the most effective for the property. To fulfil the purpose I have undertaken a comparative study where the chosen proposal of systems is compared to each other. This results in that the most energy and cost efficiency systems can be presented. The report contains a technical study which gives the basic information on the area regarding energy efficiency. The calculations of requirement regarding energy and capacity in the study are performed both by hand and with VIP-Energy. Information is also obtained by regular contact with suppliers. Regarding ventilation a comparasion between a central FTX- unit and a residential unit is made to determine which one that is the most favorable. A similar comparasion is also made regarding the heat system of the building, where a geothermal heat pump is compared to an air/water heat pump. These comparasions are made to be able to obtain both advantages and disadvantages with the systems. These are then used to determine which of the systems that is the most appropriate for the bulding. The calculations with VIP-Energy results in an energy requirement of 69 575 kWh. The capacity requirement, which is calculated by hand, results in 25 kW. The study determine that regarding the ventilation system the residential unit R2 Comfort is the most appropriate for the building. The heat pump that generates the most cost effective system is, due to this study, geothermal heat pump EcoPart 414.

Place, publisher, year, edition, pages
2016.
Keywords [sv]
Systemutredning, värmesystem, luftbehandlingssystem, VIP-Energy
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-10173OAI: oai:DiVA.org:hb-10173DiVA, id: diva2:942168
Subject / course
Energiteknik
Available from: 2016-08-04 Created: 2016-06-23 Last updated: 2016-08-04Bibliographically approved

Open Access in DiVA

fulltext(2903 kB)314 downloads
File information
File name FULLTEXT01.pdfFile size 2903 kBChecksum SHA-512
86ce4e934edd6910d0d2506672e3ba9d7905fc2501e46ff5d7b86117210396f61f2a98f1d83fcf99de7508f2515eb697b0a2c98e019d3cc9713c94dbffa3129f
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 314 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 318 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf