Mätning av fuktnivåer i betonggolv
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2016 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Measurement of moisture levels in concrete slabs (English)
Abstract [sv]

Examensarbetet redovisar försök utförda på betonggolv i syfte att studera betongens uttorkningsprocess. Testresultaten jämförs med beräkningar utförda i BI Dry och TorkaS. Betongen i testerna utsattes för fuktbelastning av olika grader och skeden. Detta skulle modellera att betong på byggen exponeras för väder och vind. Examensarbetet innehåller både litteraturstudier gällande betongensuttorkningsprocessen och tester. TorkaS 3.2, BI Dry 2.0 samt HumiGuards webbaserade beräkningsprogram användes för att beräkna uttorkningsprocessen och göra en analys av uppmätt data.

Abstract [en]

The thesis reports experiments performed on the dehydration process of moisture in concrete floor specimens. The aim is to study the RF-values in concrete exposed to humidity and for comparing actual measurements with calculation results from software. Investigation is made on the drying concrete affected by moisture at different levels and stages modelling for cases where concrete is usually exposed to weather conditions for fairly long periods before a controlled drying environment is achieved. The thesis was performed by using literature studies and tests. For each concrete slab specimen moisture controls were mounted sampling data which was implemented into the calculation program. TorkaS 3.2, BI Dry 2.0 and HumiGuard webbased calculation software was used for modelling the drying process and it is reported with graphs in the work.

Place, publisher, year, edition, pages
2016.
Keywords [sv]
Fukt, Relativ Fuktighet, RF, Betong, Byggcement, Mätningar, Uttorkning, Bi-Dry, vct
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-8862OAI: oai:DiVA.org:hb-8862DiVA, id: diva2:903815
Subject / course
Byggteknik
Available from: 2016-02-19 Created: 2016-02-17 Last updated: 2016-02-19Bibliographically approved

Open Access in DiVA

fulltext(2421 kB)1719 downloads
File information
File name FULLTEXT01.pdfFile size 2421 kBChecksum SHA-512
7b0140c47823f5a4fa40a16e8aa277ecd60052fdb7a53f9d82302019aaf20ee9f51731dba3876250144c5c8d6df254366a1b5ca213327cd9ca3bcda2defeb361
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 1720 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1490 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf