Experience with use of automated external defibrillators in out of hospital cardiac arrest
[external]. (Prehospital akutsjukvård)
[external]. (Prehospital akutsjukvård)
Show others and affiliations
1998 (English)In: Resuscitation, ISSN 0300-9572, E-ISSN 1873-1570, Vol. 37, no 1, p. 3-7Article in journal (Refereed) Published
Abstract [en]

AIM: To describe the sequences of arrhythmias, number of shocks delivered and the number of failures in a consecutive series of patients with out-of-hospital cardiac arrest attended by our emergency medical service (EMS) and in whom cardio-pulmonary resuscitation (CPR) was initiated and in whom automated external defibrillators (AEDs) were used. PATIENTS: All patients with out-of-hospital cardiac arrest attended by the EMS and in whom AEDs were used. Time for inclusion in the study: January 1st, 1987 to December 31st, 1992. RESULTS: In all there were 1781 out of hospital cardiac arrests during the study period. Among them AEDs were used in 383 cases (22%). The total number of interpreted rhythms delivered in these patients was 2719. Among all rhythm sequences coarse ventricular fibrillation (VF) was found on 375 occasions (14%); fine VF on 107 occasions (4%) and ventricular tachycardia (VT) on 12 occasions (0.4%). In ten cases with coarse VF (nine patients) the AED did not advise a shock (2.7%). In five of those nine patients a human error was interpreted as the explanation and in four there was a possible technical error. In these four patients defibrillation was delayed by 33-43 s, respectively. Among the 2225 rhythm sequences not judged as VF/VT the AED advised a shock on one occasion (0.04%). CONCLUSION: Among patients with coarse VF AED gave inaccurate instructions in 2.7%. However, the majority of the failures were judged to be caused by human errors.

Place, publisher, year, edition, pages
Elsevier Ireland Ltd , 1998. Vol. 37, no 1, p. 3-7
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:hb:diva-7860DOI: 10.1016/S0300-9572(98)00032-XLocal ID: 2320/8744OAI: oai:DiVA.org:hb-7860DiVA, id: diva2:888742
Available from: 2015-12-22 Created: 2015-12-22 Last updated: 2017-09-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Herlitz, JohanBång, A

Search in DiVA

By author/editor
Herlitz, JohanBång, A
In the same journal
Resuscitation
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 164 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf