En komparativ analys för beräkningsprogram av U-värde
University of Borås, Faculty of Textiles, Engineering and Business.
2023 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
A comparative analysis of U-value calculation programs (English)
Abstract [sv]

Detta arbete har som intention att ge en bra grund för att kunna välja vilket av programmen BISCO eller THERM som är bättre för att beräkna värmegenomgångskoefficienten U, för fönster. Syftet är formulerat utifrån att standarden EN ISO 10077-2:2012 har ersatts med den uppdaterade versionen EN ISO 10077-2:2017 där en stor skillnad är introduktionen till en ny beräkningsmetod. Denna nya beräkningsmetod är baserad på en fysikalisk teoretisk modell vid namn strålningsmodellen. BISCO möjliggör beräkning enligt båda modellerna med hjälp av en tilläggsmodul och är därför en del av syftet att jämföra numeriska resultat från båda metoderna.

Syftet med denna rapport är att finna och jämföra för- och nackdelar med att beräkna U-värdet för fönster i respektive program. Samt undersöka hur beräkningsresultaten skiljer sig åt mellan programmen med och utan beräkning enligt strålninsgmodellen. Först görs en kvalitativ jämförelse om hur programmen används och sedan en kvantitativ jämförelse baserat på beräkningsresultat. I båda programmen räknades det på tre olika fönsterprofiler där karmarna var av trä, PVC och aluminium.

Resultatet visade på att fler fördelar finns hos användandet av BISCO däremot är tidsåtgången lite större vilket beror på att programmet inte är bra anpassat för att göra ändringar i efter att man påbörjat en beräkning. Om behovet inte finns att få mer korrekta beräkningar enligt strålningsmodellen rekommenderas THERM som verktyg eftersom tidsåtgången är relativt mindre och är mindre komplex att använda. Beräkning i THERM har gett något högre värden på U än för beräkningarna i BISCO. Skillnaden med och utan strålningsmodellen är inte stornär man jämför resultaten i BISCO, däremot är det en liten skillnad gentemot THERM.

Abstract [en]

This bachelor thesis has the intention to give a good ground for selection of which calculation software, BISCO or THERM, is better for calculating the thermal transmittance U, for windows. The purpose is formulated based on the updated version of the standard EN ISO 10077-2:2012 named EN ISO 10077-2:2017. Were the big difference between these versions is the new method for calculating the heat transfer inside air cavities of the window which is based on the radiosity method. BISCO gives the user the possibility to calculate a U-values of windows with or without the new calculation method. This makes it a good program for comparing the calculation using the new and old model.

The purpose of this report is to find pros and cons with calculating the U-values for windows in the above mentioned software’s. Also to investigate how the calculation results differ from one another with and without the radiosity method. First a qualitative comparison is made of how the software’s are used and then a quantitative comparison based on the calculation results. In both BISCO and THERM, three different profiles are used where the frames are made of wood, PVC and aluminum.

The result showed that more pros are found using BISCO but more time is needed using it. Reason being that the software is not adapted for making changes after calculation already as been done. If there is not a need of more correct results according to the radiosity method, then it is recommended to use THERM because it requires relatively less time and is less complex. Calculations in THERM gave slightly higher values of the thermal transmittance then the ones calculated in BISCO. The difference with or without the radiosity method is not big at all when comparing in BISCO. However it is a little difference when comparing with results from THERM.

Place, publisher, year, edition, pages
2023.
Keywords [sv]
EN ISO 10077:2017, U-värde, Fönster, BISCO, THERM
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-30550OAI: oai:DiVA.org:hb-30550DiVA, id: diva2:1800750
Subject / course
Mechanical engineering
Supervisors
Examiners
Available from: 2023-09-29 Created: 2023-09-27 Last updated: 2023-09-29Bibliographically approved

Open Access in DiVA

En komparativ analys för beräkningsprogram av U-värde(3504 kB)430 downloads
File information
File name FULLTEXT01.pdfFile size 3504 kBChecksum SHA-512
b3ebaac1e5ec80272099648fb66a9b23e274a07c8da6bd16f541bf5915e6f7ad0d7ace896cba4e50419cd64a404610f205810fef0296b9307d3212e8775a4cd0
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 430 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 174 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf