Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
University of Borås, Faculty of Textiles, Engineering and Business.
Show others and affiliations
2023 (English)In: European Journal of Applied Physiology, ISSN 1439-6319, E-ISSN 1439-6327Article in journal (Refereed) Published
Abstract [en]

Purpose: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). Methods: Ten healthy participants received calf-NMES with increasing intensity until plantar flexion (measurement level I = ML I), and an additional mean 4 mA intensity (ML II), utilizing TTE and MPE. PVV was measured with Doppler ultrasound in the popliteal and femoral veins at baseline, ML I and II. Discomfort was assessed with a numerical rating scale (NRS, 0–10). Significance was set to p < 0.05. Results: TTE and MPE both induced significant increases in PVV from baseline to ML I and significantly higher increases to ML II, in both the popliteal and femoral veins (all p < 0.001). The popliteal increases of PVV from baseline to both ML I and II were significantly higher with TTE versus MPE (p < 0.05). The femoral increases of PVV from baseline to both ML I and II were not significantly different between TTE and MPE. TTE versus MPE resulted at ML I in higher mA and NRS (p < 0.001), and at ML II in higher mA (p = 0.005) while NRS was not significantly different. Conclusion: TTE integrated in a sock produces intensity-dependent increases of popliteal and femoral hemodynamics comparable to MPE, but results in more discomfort at plantar flexion due to higher current required. TTE exhibits in the popliteal vein higher increases of PVV compared to MPE. Trial registration: Trial_ID: ISRCTN49260430. Date: 11/01/2022. Retrospectively registered.

Place, publisher, year, edition, pages
Springer, 2023.
Keywords [en]
Electric stimulation therapy, Hemodynamics, Motor point, NMES, Pain, Textile electrodes
National Category
Textile, Rubber and Polymeric Materials
Identifiers
URN: urn:nbn:se:hb:diva-30255DOI: 10.1007/s00421-023-05212-5ISI: 000982776600001Scopus ID: 2-s2.0-85158166949OAI: oai:DiVA.org:hb-30255DiVA, id: diva2:1787863
Available from: 2023-08-15 Created: 2023-08-15 Last updated: 2024-02-21Bibliographically approved

Open Access in DiVA

fulltext(1181 kB)47 downloads
File information
File name FULLTEXT01.pdfFile size 1181 kBChecksum SHA-512
5587f3bb547346797ae124c4644d898b5a23f4b5a0b06c012337c7076b4d82eaf39411cad2843a93a133adc8957d4e368bcdb5c9b9884b4534b32538284f964a
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Guo, LiPersson, Nils-Krister

Search in DiVA

By author/editor
Guo, LiPersson, Nils-Krister
By organisation
Faculty of Textiles, Engineering and Business
In the same journal
European Journal of Applied Physiology
Textile, Rubber and Polymeric Materials

Search outside of DiVA

GoogleGoogle Scholar
Total: 53 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 100 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf