Undersökning av lämpligt tryck att tillämpa i medicinska sensoriska plagg: Vilket tryck mot huden krävs för tillförlitliga signaler från textila sensorer
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2021 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

För att kunna underlätta för sjukvården, både med avseende att belastning och för att underlätta för patienter med allergier mot t.ex. limmet som används för att fästa elektroder mot kroppen, arbetas det med att ta fram sensoriska plagg. Ett sensoriskt plagg kan användas för att kontrollera olika mätvärden i vardagen så som hjärtsignaler eller liknande och ska vara lätt för patienten att använda själv hemma. Eller som ett alternativ för någon som är allergisk mot det lim som vanligtvis används för att fästa sensorer mot kroppen. För att sensorerna i plagget ska kunna ge tydliga och användbara mätningar behöver de sitta stilla med ett jämt tryck på sensorerna mot kroppen. För att användaren av det sensoriska plagget ska vilja använda plagget och finna det bekvämt kan inte trycket mot kroppen vara för högt. Därför är det viktigt att ta reda på vilket tryck som uppfattas som bekvämt och vara funktionellt, men också är tillräckligt högt för att få en tydlig och användbar mätning. I denna rapport undersöks därför vilket tryck som uppfattas som gångbart ur användarsynpunkt. Undersökningen genomfördes med hjälp av elva deltagare som testat olika tryck och hur dessa tryck förändras under rörelse. Detta för att hitta vilket tryck deltagarna uppfattade som användbart och tillräckligt bekvämt för att använda i vardagen. Denna undersökning visa stora skillnader på vilket tryck som uppfattas som bekvämt och hur mycket trycket förändras under rörelse. Samt att statisk position inte påverkar signalerna från hjärtat anmärkningsvärt vid de undersökta trycken. 

Abstract [en]

To relieve and ease a small part of the healthcare from work overload and help patients with allergies to glue used to attach the standard sensors, a sensor-equipped wearable garment could be used. The wearable garment could be used to monitor a patient´s values during the day and should be easy for the patient to use themselves at home and comfortable to use every day, or for a patient who is allergic to the glue usually used to attach the sensors. To make the sensors on the sensor-equipped garment work the sensors must sit with pressure against the body to get readable and useful measurement. The pressure from the sensors around the body can not be too tight if it gets too uncomfortable. Therefore it is important to find what pressure that is comfortable enough for the patient to use everyday but still get good enough readings from the measuring devise to be used to monitor the patient´s values. This study looks into what pressure that the participants perceive as comfortable to use on an everyday basis. In this study the pressure is measured on eleven different participants, the pressure was measured at different times and when the participants performed different movements too document the changes in the pressure at movement to find what pressure the participants perceive as comfortable enough for everyday use. This study shows that the pressure perceived as comfortable varies between participants and that the pressure change during movement. It also shows that static position do not affect the quality of the signals from the heart at the used pressures. 

Place, publisher, year, edition, pages
2021.
Keywords [en]
Wearable garment, Pressure measurement, Medical garment, Electronic measurement, Skin electrode impedance, Anthropometry
Keywords [sv]
Sensoriska plagg, Tryckmätning, Medicinska plagg, Elektroniska mätningar, Hud-elektrodimpedans, Antropometri  
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-26576OAI: oai:DiVA.org:hb-26576DiVA, id: diva2:1600069
Available from: 2021-10-07 Created: 2021-10-04 Last updated: 2021-10-07Bibliographically approved

Open Access in DiVA

fulltext(1940 kB)78 downloads
File information
File name FULLTEXT01.pdfFile size 1940 kBChecksum SHA-512
b28948ecfde3016893cf6c67514eff5dc4a9b4fb48b066bab93613e4b5a32ea8fcc395f41655bf2e8f8acd0febfc21ccd71a8a72d579b4a905db7a6e50edf4bd
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 78 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 130 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf