Nollpunktsproblematik i Varbergs tätort – samt lösningsförslag
University of Borås, Faculty of Textiles, Engineering and Business.
2019 (Swedish)Independent thesis Basic level (university diploma), 180 HE creditsStudent thesisAlternative title
Neutral point problems in Varberg’s urban area – and solutions (English)
Abstract [sv]

Nollpunktsreaktorer används för att kompensera bort den kapacitiva jordslutningsström som uppstår i kablar och ledningar i impedansjordade elnät. Dess funktion är mycket viktigt för att inte riskera stora urladdningsströmmar i händelse utav ett fel i elnätet och fyller därmed ett stort säkerhetsmässigt syfte. Varberg Energi har på sitt område fyra stycken mottagningsstationer i vilka överliggande regionnät (130 kV) transformeras ner till lokalnätsnivå (10 kV). De tre mottagningsstationer som innefattas i Varbergs tätort är på 10kV-sidan förbundna med så kallade starka kabelförband, för att möjliggöra redundanta matningsvägar i det fall då överliggande regionnät av någon anledning måste kopplas bort. Vid användning utav dessa kabelförband uppstår problematik kring mottagningsstationernas nollpunktsreaktorer, detta då den kapacitiva jordslutningsströmmen i vissa kopplingslägen blir för stor. Då detta äventyrar nollpunktsreaktorns funktion behöver detta fenomen på något sätt åtgärdas. Examensarbetet har haft som syfte att beskriva olika typer utav nollpunktsutrustning och vilka aspekter som behövs ta hänsyn till vid investering i ny utrustning i Varbergs tätort, även har lösningar tillsammans med förenliga kostnader presenterats. Inledningsvis gjordes en inventering utav befintlig nollpunktsutrustning, där dess skick, regleringsmöjligheter, inställda värden samt maximala kompenseringsförmåga kartlagts. Teoretiska driftfall i vilka laster flyttas mellan mottagningsstationerna beräknades med hjälp utav inventerade parametrar, vilka sedan användes för att lägga grunden till de lösningsförslag som presenteras. Lösningsförslaget innefattar att istället för att använda sig utav matande transformators nollpunkt koppla nollpunktsreaktorn mot en nollpunktsbildare, vilka gör att kompensering utav den kapacitiva jordslutningströmmen inte längre blir beroende utav att transformatorn är spänningssatt. I och med detta kan nollpunktsreaktorerna hållas i drift även utan matning från överliggande regionnät.

Abstract [en]

Arc suppression coils are used to compensate the capacitive earth fault currents that is generated in cables and power lines in resonant grounded electrical grids. Its function is very important to reduce the amount of fault current in an event of a fault in the electrical grid and it therefore fills a significant safety purpose. The electrical grid owned by Varberg Energi houses four main switchgear stations where regional electrical grid (130 kV) is transformed to the local power grid (10 kV). The three switchgear stations located in the urban area of Varberg are connected via cables used to transport big amount of power from one station to another for redundancy purposes, if the regional grid for whatever reason needs to be disconnected. Sometimes when these cables are used problems occur due to the size of the capacitive earth fault current. These problems sometimes cause the arc suppression coils to fail to compensate the capacitive earth fault current, therefore this issue needs to be resolved. This bachelor thesis main goals have been to describe different kinds of neutral point equipment, which aspects that needs to be considered when investing in new equipment, also ways to solve the problem together with the cost to do so. Initially the neutral point equipment currently used has been mapped with emphasis on its condition, control possibilities, operation parameters and maximum capacity to compensate capacitive earth leaking current. These parameters where used to calculate theoretical operation modes when load was moved from one switchgear station to another, which whom where used to choose the right equipment to solve the issue. The solution presents a way where the arc suppression coil is connected to a grounding transformer instead of using the neutral point on regular transformer. Due to this the arc suppression coil no longer is dependent on the power transformer and can still be used even without voltage from the regional power grid.

Place, publisher, year, edition, pages
2019.
Keywords [sv]
Nollpunktsreaktor nollpunktsbildare Kapacitiva jordsslutningsströmmar Reläskydd
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-22938OAI: oai:DiVA.org:hb-22938DiVA, id: diva2:1410969
Subject / course
Energiteknik - Högskoleingenjör
Supervisors
Examiners
Available from: 2020-03-03 Created: 2020-03-02 Last updated: 2020-03-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 229 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf