Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Minimering av transmissionsförluster i ett flerbostadshus
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2019 (Swedish)Independent thesis Basic level (university diploma), 180 HE creditsStudent thesisAlternative title
Minimization of transmission losses in a multi-family house (English)
Abstract [sv]

I denna rapport undersöks hur transmissionsförluster och Umedel-värde (Um-värde) hos ett flerbostadshus kan minimeras. Då kraven på byggnaders prestanda, avseende transmissionsförluster och Um-värde, gradvis skärps har rapporten dignitet och denna kan ligga till grund för framtida strategier och lösningar inom området. Syftet med denna rapport är att undersöka hur det går att minimera transmissionsförluster och Um-värde, med utgång från en befintlig byggnad, genom att ändra fönsterandel, materialval och byggnadens utformning. För att besvara forskningsfrågan: Hur kan transmissionsförluster och Um-värde minimeras i ett flerbostadshus med avseende till faktorerna fönsterandel, materialval och byggnadensutformning, genomförs en fallstudie. Huset i fallstudien som ligger till grund för beräkningarna i rapporten är ett flerbostadshus, Klockaren 2, i Pålsjö i Helsingborgs kommun. Resultatdelen är baserad på befintliga ritningar och beskrivningar samt ett teoretiskt ramverk. Av dessa beräknas transmissionsförluster och Um-värde för sex nya typer av Klockaren 2. I de nya typerna har fönsterandel, materialval och byggnadens utformning optimerats för att minimera transmissionsförluster och Um-värde i enlighet med rapportens teoretiska ramverk. Resultaten från beräkningarna mynnar ut i en diskussionsdel där de olika typerna vägs mot varandra samt vilka eventuella problem och fördelar de olika typerna kan tänkas medföra. Delen berör även det tidvis motstridiga förhållandet mellan minimering av transmissionsförluster och minimering av Um-värde. Rapportens användningsområden samt förslag till framtida forskning som ligger i linje med rapporten lyfts fram. Slutsatsen från rapporten blir att det det går att sänka Um-värdet och transmissionsförlusterna genom att ändra materialval och fönsterandelen. I slutsatsen fastslås även att om en optimering genomförs enbart med fokus på Um-värde får byggnaden en helt annan utformning än om fokus enbart läggs på att optimeratransmissionsförlusterna.

Abstract [en]

This report examines how transmission losses and Umid value (Um value) of a multi-dwelling house can be minimized. As the demands on the performance of buildings, regarding transmission losses and Um value, are gradually tightened, the report has dignity and this can form the basis for future strategies and solutions in the area. The purpose of this report is to investigate how it is possible to minimize transmission losses and Um value with an output from an existing building by changing the window part, the choice of material and the design of the building.To answer the research question: How can transmission losses and Um value be minimized in a multi-dwelling building with respect to the factors of window share, choice of materials and the design of the building, is a case study is carried out. The house in the case study that forms the basis of the calculations in the report is a multi-dwelling house, Klockaren 2, in Pålsjö in the municipality of Helsingborg. The result section is based on existing drawings and descriptions as well as a theoretical framework. Of these, transmission losses and Um value are calculated for six new types of the Klockaren 2. In the new types, window parts, choice of materials and the design of the building have been optimized to minimize transmission losses and Um value in accordance with the report's theoretical framework. The results from the calculations result in a discussion part where the different types are weighed against each other and what possible problems and advantages the different types might bring about. The part also touches on the occasionally conflicting relationship between minimizing transmission losses and minimizing Um value. The use of the report and proposals for future research that are in line with the report are highlighted. The conclusion from the report is that it is possible to lower the Um value and the transmission losses by changing the choice of material and the window share. The conclusion also states that if an optimization is carried out solely with the focus on Um value, the building will have a completely different design than if focus is only placed on optimizing the transmission losses.

Place, publisher, year, edition, pages
2019.
Keywords [sv]
Transmissionsförluster, U-värde, Formfaktor, Fönsterandel, Materialval, Flerbostadshus, BBR
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-22928OAI: oai:DiVA.org:hb-22928DiVA, id: diva2:1410922
Subject / course
Industriell ekonomi - Högskoleingenjör
Supervisors
Examiners
Available from: 2020-03-03 Created: 2020-03-02 Last updated: 2020-03-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 204 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf