Uttorkning av prefab betongbjälklag
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2019 (Swedish)Independent thesis Basic level (university diploma), 180 HE creditsStudent thesisAlternative title
Drying of prefabricated concrete slabs (English)
Abstract [sv]

Stora problem med fukt i byggnader som kan relateras till så kallad byggfukt rapporteras årligen. Problematiken med tätt ytskikt på betong uppmärksammas i större utsträckning. I skolor och på sjukhus där det ofta finns krav på lättstädade miljöer är problemet som störst, då det i dagsläget enda alternativet verkar vara en tät plastmatta. Att lägga ett tätt ytskikt på betong ställer krav på uttorkning av konstruktionen, betongen ska ha en relativ fuktighet (RF) som är högst 85% innan plastmatta får läggas. Detta för att undvika att fukten i konstruktionen bryter ner limmet, vilket på sikt skulle kunna orsaka skador på byggnader i form av mögel och mikrobiell tillväxt. Personer som vistas i dessa miljöer kan uppleva hälsobesvär. I form av huvudvärk, trötthet, koncentrationsbesvär, irritation och torrhetskänsla i ögon, näsa, hals och hud.

Detta examensarbete är en studie genomförd i samarbete med UBAB, Ulricehamns betong, som syftar till att jämföra inverkan av förhållandet mellan vatten och cement (vct) i betongreceptet samt hur förvaringsmiljön påverkar RF. Tre av UBAB:s recept har jämförts. Varav ett recept med lågt vct som är framtaget specifikt för att förkorta uttorkningstiden. För varje recept gjöts två plattor, där den ena förvarades utomhus och den andra inomhus under perioden slutet av januari till slutet av maj. Mätningen av RF skedde genom borrhålsmätning enligt RBK:s manual för fuktmätning. En jämförandemätning gjordes också med uttagsprov.

Resultaten visade tydligt att plattorna som förvarades inomhus hade ett lägre RF än de som förvarats utomhus. De recepten med lägre vct hade ett lägre RF än de med högre vct. Av de plattor som förvarades utomhus hade plattan med lägst vct det lägsta RF, vilket var högre än RF hos samtliga plattor som förvarats inomhus. Uttagsproven bekräftade detta, även om dessa resultat kraftigt underskattade RF.

En jämförelse mellan prognosvärden i TorkaS och borrhålsmätningen visade att TorkaS inte överensstämmer med de avlästa värdena. TorkaS prognostiserar högre RF för prov som förvaras inne. För prover som förvaras ute beräknas ett lägre RF än avläst.

Abstract [en]

Major problems with moisture in buildings that can be related to so-called building moisture arereported annually. The problem with dense surface layer on top of concrete slab becomes more common. In schools and hospitals, the environment requires floors that are easy to clean, and the only solution is to use a plastic mat. A plastic mat on a concrete slab demands that the relative humidity (RH) must be below 85 %. This to prevent moisture from dissolve the glue which could lead to microbial growth and mold. People staying daily in this kind of environment could suffer from health issues. Suchas headaches, fatigue, concentration problems, irritation and dryness in eyes, nose, throat and skin.

This report in collaboration with UBAB, Ulricehamns betong, is comparing how the different recipes of concrete and the climate of storage will impact on RH. The recipes used are three of UBAB: s standardrecipes. One recipe with low water-cement ratio wich is created to shorten the time for the concreteto dry. Two slabs are made for each recipe, one is stored outdoors and the other one indoors during the period January to May. The method used to measure the RH is by drilling hole in the concrete and make measurements according to RBK standards. A comparing study is made with removed concrete from slab to test tubes. RH is then measured in a climate cabinet.

The results show that slabs stored indoors have a lower RH compared to the slabs that have been stored outdoors. The slab with low water-cement ratio stored outdoors has the lowest RH of the outdoor slabs, but still higher than all slabs that have been stored indoors. Results from test with removed concrete confirmed how the environment of storage has large impact on the speed of drying. Although the values of RH were too low to be trusted.

Calculations made with TorkaS does not match the results from measurements. TorkaS overestimates RH for slabs stored outdoors. RH for slabs stored indoors are underestimated by TorkaS.

Place, publisher, year, edition, pages
2019.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-22409OAI: oai:DiVA.org:hb-22409DiVA, id: diva2:1385017
Supervisors
Examiners
Available from: 2020-01-13 Created: 2020-01-13 Last updated: 2020-01-13Bibliographically approved

Open Access in DiVA

fulltext(4066 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 4066 kBChecksum SHA-512
0bb14bf27c4ad47a61978f3d1d088fa6d745b8a30be986bbc92e85f207697a44818830ea87018486cc843cd4fc8615c7a0284a50f30dce5643010f253f10957a
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 8 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-cite-them-right
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf