Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
3D kroppsskanning som antropometriskt verktyg för individanpassad protesstrumpa
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2019 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Varje ar genomgår ca 3000 personer i Sverige amputation av nedre eller övre extremitet. För att förbättra passformen av protesen och samtidigt förbättra komforten för personen som bär den kan en protesstrumpa användas. För högsta komfort kan protesstrumpan individanpassas och för att möjliggöra detta kan måtten tas med hjälp av en 3D kroppsskanner. Traditionell måttagning såväl som måttagning med hjälp av 3D kroppsskannnern innebär en standardiserad positionering som kan uppfattas som svår för personer med en amputationsstump. För att kunna skanna en amputationsstump behövs därmed en ny och anpassad metod för detta scenario utvecklas. Syftet med studien är att utforma ett skanningsscenario och en algoritm for 3D kroppsskanning av amputationsstump med avsikt att individanpassa protesstrumpor.

3D kroppsskannern som användes genom studien är VITUSSMART LC 3D-body Scanner fran Vitronic. En inledande förstudie genomfördes för att konstruera ett mätnings-/skanningsscenario för skanning av amputationer av överkroppens extremiteter. Det utvecklade skanningsscenariot testades sedan på åtta frivilliga testpersoner. Kroppskanningen utfordes två gånger i båda vinklarna (totalt fyra skanningar per testobjekt) och den manuella mätningen utfördes två gånger. Datan från måttagningen analyserades genom olika statistiska beräkningar.

Resultatet från förstudien visade att position X, en sittande position med armarna lätt ut från kroppen, gav bäst resultat. För att få ut mått på vänster överarm och höger axill, skannas positionen i 45◦ vinkel i skanningsutrymmet. For att få ut mått på höger överarm och vänster axill skannas positionen i 315◦. Det parade t-testet visade ingen signifikant skillnad mellan måttagningsmetoderna. Studien visar även hög extern reliabilitet. Vidare studier bör göras med ett större stickprov. Även en tillämpning av studien bör göras på personer med en amputationsstump för att undersöka metodens genomförbarhet.

Abstract [en]

Every year, 3000 people in Sweden undergoes an amputation of extremities. To improve the fit and the comfort of the prosthesis a prost-hesis sock can be used as an interface between the socket and the stump. To achieve higher fit and comfort the prosthesis sock can be individualised to the person that will wear it. To facilitate this process, the measurements of the stump can be taken by a 3D body scanner. Both traditional measurements and measurements taken with the 3D body scanner requires a standardised posture, witch can be hard for people with an amputee stump to adopt, a new scanning method for this scenario needs to be developed. The purpose of this study is to create a scanning scenario and an algorithm for body scanning of amputation stumps with the aim to individualise prosthesis socks.

The scanner that have been used in this study is the VITUSSMART LC 3D-body Scanner from Vitronic. To create a scanning/measuring sce-nario for scanning of amputee stumps, a pilot study was accomplished. The developed scanning scenario were then tested on 8 voluntary test subjects. The scanning scenario was performed two times for each subject (a total of four scans) and the manual measurements were taken independently by each of the authors. The collected data was then analysed with different statistical calculations.

The result of the pilot study showed that the position X, a seated posture with arms slightly away from the body, gave the best result. Position X will be scanned in a 45◦ angle to measure left upper arm and right armpit. To measure the right upper arm and left armpit, the posture will be scanned in a 315◦ angle. The paired t-test showed that there were no significant difference between the two measuring methods. The study also showed high relative reliability. Further studies needs to be done on a larger sample but it also should be tested on persons with an amputee stump.

Place, publisher, year, edition, pages
2019.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-22023OAI: oai:DiVA.org:hb-22023DiVA, id: diva2:1370209
Subject / course
Textilteknologi
Available from: 2019-11-15 Created: 2019-11-14 Last updated: 2019-11-15Bibliographically approved

Open Access in DiVA

fulltext(8679 kB)0 downloads
File information
File name FULLTEXT01.pdfFile size 8679 kBChecksum SHA-512
402f9e052b130a80f4c2f9432bd17ea59ecc055c65cbc17f1aac1c733caac1dc2688159b72df88775808ef3d9cb62f8baf351ce46154eff8a520ecfb0fbc40df
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 5 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf