Implementation of and Electrical Bioimpedance Measurement System for Renal Function Monitoring
University of Borås, School of Engineering.
2008 (English)Independent thesis Advanced level (degree of Master (One Year))Student thesis
Abstract [en]

Peritoneal Dialysis is a treatment for patients suffering from renal failure that allows out-patient care. This means that the patient only needs to visit the hospital for consultation and not for treatment, increasing considerably the comfort of the patient, while reducing remarkably the cost per patient. In order to increase the level of medical supervision obtained with the periodic visits to the clinic, televisit has been put into practice in some hospitals. But these televisits are based on indirect and qualitative indicators of renal failure, and therefore they are just valid for detection of situations near limit cases, such as well over-hydrated or dehydrated. Electrical Bioimpedance Measurements have been proved to constitute an appropriate method for assessment of body composition, and therefore they can provide with direct indicators of body fluid distribution. Such ability of EBI technology allows the detection of body fluid unbalance caused by renal dysfunction, and therefore, nephrology televisits would benefit tremendously from EBI measurements. This project is based on the AD5933 Impedance Network Analyzer of Analog Devices, and the main task is to develop a software application that controls the evaluation board in which it is implemented, and allows the storage of the EBI measurements in EDF+ files that will facilitate the management of medical data when applied to televisit. These files are uploaded to XML format in order to be sent to a remote server, where a software application will have been implemented for medical consultation.

Place, publisher, year, edition, pages
University of Borås/School of Engineering , 2008.
Series
Magisteruppsats
Keywords [en]
electrical bioimpedance, renal failure, peritoneal dialysis, 4-electrode method, portable, telemedicine, home healthcare
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-18839Local ID: 2320/3650OAI: oai:DiVA.org:hb-18839DiVA, id: diva2:1310773
Note
Uppsatsnivå: DAvailable from: 2019-04-30 Created: 2019-04-30

Open Access in DiVA

fulltext(2854 kB)29 downloads
File information
File name FULLTEXT01.pdfFile size 2854 kBChecksum SHA-512
84efc601da2029d605daa85dbfc5e7fb51f06758fdfe2c83b6eaddfb7a22a04c8654a1167d438052052f0492010ebea90fc65b29d3758e79b9249389f98de572
Type fulltextMimetype application/pdf

By organisation
School of Engineering
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 29 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 3 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf