Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Geoanläggning i Nya Krokslätt – Beskrivning och utvärdering av driften
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2018 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Geothermal plant in Nya Krokslätt – Description and evaluation of the operation (English)
Abstract [sv]

När krav på fler förnyelsebara energikällor ställs har teknikområdet geoenergi succesivt utvecklats för att med berggrundens egenskaper och kylvärmepumpar förse såväl värme- som kylbehov inom olika sektorer. Då sektorn bostäder och fastigheter stod för cirka 40 % av Sveriges totala slutgiltiga energianvändning år 2015 finns möjligheter att utvecklingen av geoanläggningar ska kunna minska miljöpåverkan samtidigt som det sänker energianvändningen såväl som kostnader. På beställning av Husvärden AB byggdes geoanläggningen Mediacentralen i området Nya Krokslätt i Mölndal. Tre kylvärmepumpar i anläggningen förser området med kyla och värme året runt. Mediacentralen inrymmer ett stort antal komponenter som är vitala för att upprätthålla driften för såväl kyl- som värmedrift. Syftet med detta arbete är att åskådliggöra och beskriva hur en större bergvärmeanläggning i Nya Krokslätt fungerar samt utreda hur driften har varit och ifall det finns förbättringar att utföra. Genom att erhålla mätvärden från anläggningen och behandla dessa med olika program- och mjukvaror kan analyser av enskilda komponenter såväl som den generella driften utföras. Under arbetets gång har det inte framkommit några konkreta problem i driften av Mediacentralen, däremot har det kunnat fastslås att insamlingen av mätdatan är bristfällig och att förbättringsmöjligheterna försvåras på grund av detta. Skillnaden i drifttiden mellan två av kylvärmepumparna är i storleken 3000 timmar sen driftsättningen av anläggningen 2015. Detta tyder på fel i mätvärdesloggningen, då mätvärden beträffande energianvändning och kapacitet visar motsatsen. Även kylvärmepumparnas värmefaktor, det mått som ger deras effektivitet, skiljer sig markant från månad till månad vilket ger en indikation om att något kan förbättras på lång sikt.

Abstract [en]

When demands are made for more renewable energy sources, the geoenergy technology has been developed gradually to provide heating and cooling in the various sectors with the bedrocks properties and heat pumps. Since the housing and real estate sector accounted for about 40% of Sweden's total final energy use in 2015, opportunities for the development of geo-plants can reduce environmental impact while reducing energy useage as well as costs. At the request of Husvärden AB, the geo-plant called Mediacentralen was built in the Nya Krokslätt area in Mölndal. Three refrigeration heat pump in the plant provides the area with cooling and heating all year round. Mediacentralen houses a large number of components that are vital for maintaining the operation of both cooling and heating operations. The purpose of this work is to illustrate and describe how a larger geothermal-plant in New Krokslätt works, as well as investigate how the operation has been and if there are improvements to perform. By obtaining measurement values from the plant and processing them with various software, analyzes of individual components as well as the general operations can be performed.During the course of the work no concrete problems have been encountered in the operation of the Mediacentral. On the other hand, it has been found that the collection of the measurement data is insufficient and that the improvement possibilities were aggrivated by this. The difference in operating time between two of refrigeration heat pumps is 3000 hours since the commissioning of the facility 2015 indicates errors in the measurement value logging, as the measurement of energy use and capacity shows the opposite. Even the heat factor of the refrigeration heat pump, the measure that provides their efficiency, differs significantly from month to month, giving an indication that something can be improved in the long run.

Place, publisher, year, edition, pages
2018.
Keywords [sv]
Bergvärme, kylvärmepump, geoanläggning, utvärdering, borrhål
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-14980OAI: oai:DiVA.org:hb-14980DiVA, id: diva2:1238674
Subject / course
Energiteknik
Available from: 2018-08-15 Created: 2018-08-14 Last updated: 2019-08-27Bibliographically approved

Open Access in DiVA

fulltext(1954 kB)298 downloads
File information
File name FULLTEXT01.pdfFile size 1954 kBChecksum SHA-512
3dc84c0897c67485d9d3bbc4a8e36d867ba41b074a8a13fcdae256a934ae9159caff0f8131325fc330344229adf02036be4543e2ac13341a327a55dfc1ef7f01
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 299 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 366 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf