Experience with use of automated external defibrillators in out of hospital cardiac arrest
[external]. (Prehospital akutsjukvård)
[external]. (Prehospital akutsjukvård)
Vise andre og tillknytning
1998 (engelsk)Inngår i: Resuscitation, ISSN 0300-9572, E-ISSN 1873-1570, Vol. 37, nr 1, s. 3-7Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

AIM: To describe the sequences of arrhythmias, number of shocks delivered and the number of failures in a consecutive series of patients with out-of-hospital cardiac arrest attended by our emergency medical service (EMS) and in whom cardio-pulmonary resuscitation (CPR) was initiated and in whom automated external defibrillators (AEDs) were used. PATIENTS: All patients with out-of-hospital cardiac arrest attended by the EMS and in whom AEDs were used. Time for inclusion in the study: January 1st, 1987 to December 31st, 1992. RESULTS: In all there were 1781 out of hospital cardiac arrests during the study period. Among them AEDs were used in 383 cases (22%). The total number of interpreted rhythms delivered in these patients was 2719. Among all rhythm sequences coarse ventricular fibrillation (VF) was found on 375 occasions (14%); fine VF on 107 occasions (4%) and ventricular tachycardia (VT) on 12 occasions (0.4%). In ten cases with coarse VF (nine patients) the AED did not advise a shock (2.7%). In five of those nine patients a human error was interpreted as the explanation and in four there was a possible technical error. In these four patients defibrillation was delayed by 33-43 s, respectively. Among the 2225 rhythm sequences not judged as VF/VT the AED advised a shock on one occasion (0.04%). CONCLUSION: Among patients with coarse VF AED gave inaccurate instructions in 2.7%. However, the majority of the failures were judged to be caused by human errors.

sted, utgiver, år, opplag, sider
Elsevier Ireland Ltd , 1998. Vol. 37, nr 1, s. 3-7
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-7860DOI: 10.1016/S0300-9572(98)00032-XLokal ID: 2320/8744OAI: oai:DiVA.org:hb-7860DiVA, id: diva2:888742
Tilgjengelig fra: 2015-12-22 Laget: 2015-12-22 Sist oppdatert: 2017-09-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Herlitz, JohanBång, A

Søk i DiVA

Av forfatter/redaktør
Herlitz, JohanBång, A
I samme tidsskrift
Resuscitation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 112 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf