Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Skin-Electrode Contact Area in Electrical Bioimpedance Spectroscopy. Influence in Total Body Composition Assessment.
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.ORCID-id: 0000-0003-4853-7731
2011 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Electrical Bioimpedance Spectroscopy (EBIS) has been widely use for assessment of total body composition and fluid distribution. (EBIS) measurements are commonly performed with electrolytic electrodes placed on the wrist and the ankle with a rather small skin–electrode contact area. The use of textile garments for EBI requires the integration of textrodes with a larger contact area surrounding the limbs in order to compensate the absence of electrolytic medium commonly present in traditional Ag/AgCl gel electrodes. Recently it has been shown that mismatch between the measurements electrodes might cause alterations on the EBIS measurements. When performing EBIS measurements with textrodes certain differences have been observed, especially at high frequencies, respect the same EBIS measurements using Ag/AgCl electrodes. In this work the influence of increasing the skinelectrode area on the estimation of body composition parameters has been study performing experimental EBIS measurement. The results indicate that an increment on the area of the skin-electrode interface did produce noticeable changes in the bioimpedance spectra as well as in the body composition parameters. This influence must be taken into consideration when designing and testing textile-enable EBIS measurement systems.

sted, utgiver, år, opplag, sider
IEEE , 2011.
Emneord [en]
impedance, textile electrodes, EBIS, biomedica engineering, Biomedical Engineering
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-6722DOI: 10.1109/IEMBS.2011.6090530Lokal ID: 2320/10168ISBN: 978-1-4244-4121-1 (tryckt)OAI: oai:DiVA.org:hb-6722DiVA, id: diva2:887424
Konferanse
33st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, USA Sept, 2011.
Tilgjengelig fra: 2015-12-22 Laget: 2015-12-22 Sist oppdatert: 2017-11-09

Open Access i DiVA

fulltekst(303 kB)389 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 303 kBChecksum SHA-512
f381f87c5870033618a544c4207500da06cde1ec779a19125697dc371d135f9ffc4ebcefee57aa1a0abcd629a21f28a106f6e2ac82c11246aa0a6da1e7b9bf40
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Personposter BETA

Marquez Ruiz, Juan CarlosSeoane, FernandoLindecrantz, Kaj

Søk i DiVA

Av forfatter/redaktør
Marquez Ruiz, Juan CarlosSeoane, FernandoLindecrantz, Kaj
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 389 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 208 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf