Performance of the Load-in-the-Loop Single Op-Amp Voltage Controlled Current Source from the Op-Amp Parameters
(Biomedical Engineering)
Högskolan i Borås, Institutionen Ingenjörshögskolan. (Biomedical Engineering)
(Biomedical Engineering)
2010 (Engelska)Ingår i: Journal of Physics: Conference Series, Institute of Physics Publishing Ltd. , 2010Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

In recent years, Electrical Bioimpedance (EBI) methods have gained importance. These methods are often based on obtaining impedance spectrum in the range of β-dispersion, i.e. from a few kHz up to some MHz. To measure EBI a constant current is often injected and the voltage across the tissue under study (TUS) is recorded. Due to the performance of the current source influences the performance of the entire system, in terms of frequency range, several designs have been implemented and studied. In this paper the basic structure of a Voltage-Controlled Current Source (VCCS) based on a single Op-Amp in inverter configuration with a floating load, known as load-in-the-loop current source, is revisited and studied deeply. We focus on the dependence of the output impedance with the circuit parameters, i.e. the feedback resistor and the inverter-input resistor, and the Op-Amp main parameters, i.e. open loop gain, CMRR and input impedance. After obtaining the experimental results and comparing to the theoretical and simulated ones, they confirm the design under study can be a good solution for multi-frequency wideband EBI applications because of higher values of the output impedance than 100kΩ at 1MHz are obtained. Furthermore, an enhancement of the basic design, using a current conveyor as a first stage, is proposed, studied and implemented.

Ort, förlag, år, upplaga, sidor
Institute of Physics Publishing Ltd. , 2010.
Nyckelord [en]
electronic instrumentation, bioimpedance, measurement instrumentation, Medical Electronics
Nationell ämneskategori
Elektroteknik och elektronik Biomedicinsk laboratorievetenskap/teknologi
Identifikatorer
URN: urn:nbn:se:hb:diva-6300DOI: 10.1088/1742-6596/224/1/012008Lokalt ID: 2320/5949OAI: oai:DiVA.org:hb-6300DiVA, id: diva2:886987
Konferens
XIVth International Conference on Electrical Bioimpedance, Florida, USA
Tillgänglig från: 2015-12-22 Skapad: 2015-12-22 Senast uppdaterad: 2017-10-20Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltexthttp://iopscience.iop.org/1742-6596/224/1/012008

Personposter BETA

Seoane, Fernando

Sök vidare i DiVA

Av författaren/redaktören
Seoane, Fernando
Av organisationen
Institutionen Ingenjörshögskolan
Elektroteknik och elektronikBiomedicinsk laboratorievetenskap/teknologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 121 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf