Effects on hemodynamic enhancement and discomfort of a new textile electrode integrated in a sock during calf neuromuscular electrical stimulation
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden.
Högskolan i Borås, Akademin för textil, teknik och ekonomi.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: European Journal of Applied Physiology, ISSN 1439-6319, E-ISSN 1439-6327Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To compare fixed transverse textile electrodes (TTE) knitted into a sock versus motor point placed standard gel electrodes (MPE) on peak venous velocity (PVV) and discomfort, during calf neuromuscular electrical stimulation (calf-NMES). Methods: Ten healthy participants received calf-NMES with increasing intensity until plantar flexion (measurement level I = ML I), and an additional mean 4 mA intensity (ML II), utilizing TTE and MPE. PVV was measured with Doppler ultrasound in the popliteal and femoral veins at baseline, ML I and II. Discomfort was assessed with a numerical rating scale (NRS, 0–10). Significance was set to p < 0.05. Results: TTE and MPE both induced significant increases in PVV from baseline to ML I and significantly higher increases to ML II, in both the popliteal and femoral veins (all p < 0.001). The popliteal increases of PVV from baseline to both ML I and II were significantly higher with TTE versus MPE (p < 0.05). The femoral increases of PVV from baseline to both ML I and II were not significantly different between TTE and MPE. TTE versus MPE resulted at ML I in higher mA and NRS (p < 0.001), and at ML II in higher mA (p = 0.005) while NRS was not significantly different. Conclusion: TTE integrated in a sock produces intensity-dependent increases of popliteal and femoral hemodynamics comparable to MPE, but results in more discomfort at plantar flexion due to higher current required. TTE exhibits in the popliteal vein higher increases of PVV compared to MPE. Trial registration: Trial_ID: ISRCTN49260430. Date: 11/01/2022. Retrospectively registered.

Ort, förlag, år, upplaga, sidor
Springer, 2023.
Nyckelord [en]
Electric stimulation therapy, Hemodynamics, Motor point, NMES, Pain, Textile electrodes
Nationell ämneskategori
Textil-, gummi- och polymermaterial
Identifikatorer
URN: urn:nbn:se:hb:diva-30255DOI: 10.1007/s00421-023-05212-5Scopus ID: 2-s2.0-85158166949OAI: oai:DiVA.org:hb-30255DiVA, id: diva2:1787863
Tillgänglig från: 2023-08-15 Skapad: 2023-08-15 Senast uppdaterad: 2023-08-29Bibliografiskt granskad

Open Access i DiVA

fulltext(1181 kB)9 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1181 kBChecksumma SHA-512
5587f3bb547346797ae124c4644d898b5a23f4b5a0b06c012337c7076b4d82eaf39411cad2843a93a133adc8957d4e368bcdb5c9b9884b4534b32538284f964a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextScopus

Person

Guo, LiPersson, Nils-Krister

Sök vidare i DiVA

Av författaren/redaktören
Guo, LiPersson, Nils-Krister
Av organisationen
Akademin för textil, teknik och ekonomi
I samma tidskrift
European Journal of Applied Physiology
Textil-, gummi- och polymermaterial

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 9 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 39 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf