Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Textile Electrodes: Influence of Electrode Construction and Pressure on Stimulation Performance in Neuromuscular Electrical Stimulation (NMES)
University of Borås.
Karolinska institutet.
Karolinska institutet.
University of Borås, Faculty of Textiles, Engineering and Business.
Show others and affiliations
2021 (English)In: Engineering in Medicine & Biology Society (EMBC), 2021 43rd Annual International Conference of the IEEE, IEEE, 2021, p. 1305-1308Conference paper, Published paper (Refereed)
Sustainable development
According to the author(s), the content of this publication falls within the area of sustainable development.
Abstract [en]

The major reason for preventable hospital death isvenous thromboembolism (VTE). Non-pharmacologicaltreatment options include electrical stimulation or compressiontherapy to improve blood flow in the extremities. Textileelectrodes offer potential to replace bulky devices commonlyused in this field, thereby improving the user compliance. In thiswork, the performance of dry and wet knitted electrodes incombination with pressure application to the electrode wasevaluated in neuromuscular electrical stimulation (NMES). Amotor point stimulation on the calf was performed on ninehealthy subjects to induce a plantarflexion and the requiredstimulation intensity as well as the perceived pain were assessed.The performance of the different electrode constructions wascompared and the influence of the pressure application wasanalysed. The results show that wet textile electrodes (0.9 %saline solution) perform significantly better than dry electrodes.However, opportunities were found for improving theperformance of dry textile electrodes by using an uneven surfacetopography in combination with an intermediate to highpressure application to the electrode (> 20 mmHg), e.g. by usinga compression stocking. Moreover, the smaller of the two testedelectrode areas (16 cm2; 32 cm2) appears to be favourable interms of stimulation comfort and efficiency.

Place, publisher, year, edition, pages
IEEE, 2021. p. 1305-1308
National Category
Other Medical Engineering
Research subject
Textiles and Fashion (General)
Identifiers
URN: urn:nbn:se:hb:diva-27097DOI: 10.1109/EMBC46164.2021.9630649Scopus ID: 2-s2.0-85122528542ISBN: 978-1-7281-1179-7 (print)OAI: oai:DiVA.org:hb-27097DiVA, id: diva2:1621850
Conference
2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) Oct 31 - Nov 4, 2021. Virtual Conference
Available from: 2021-12-20 Created: 2021-12-20 Last updated: 2022-02-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Euler, LuisaGuo, LiPersson, Nils-Krister

Search in DiVA

By author/editor
Euler, LuisaGuo, LiPersson, Nils-Krister
By organisation
University of BoråsFaculty of Textiles, Engineering and Business
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 54 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf