Studie av ventilation i simhall: Med fokus på klorbaserade luftföroreningar
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Study of Ventilation in Public Baths : Focusing on chlorine-based air pollution (English)
Abstract [sv]

Allmänna bad bidrar i hög grad till att främja allmänhetens hälsa och välbefinnande. De erbjuder möjlighet till motion och rekreation för människor i alla åldrar. För att badgäster ska trivas och må bra krävs det att vatten- och luftkvalitet håller hög nivå. I syfte att förhindra spridning av sjukdomsalstrande organismer mellan badgäster används klor som en central komponent för att desinficera vattnet. Kloret lämnar dock restprodukter efter sig, främst trikloramin som påverkar människors hälsa negativt. Trikloramin samlas över vattenytan och stannar kvar i andningszonen om inte föroreningarna transporteras bort via luftrörelser.I Nolhaga simhall sker fram till 2018 en ombyggnad av anläggningen. Rapporten berör den nya ventilationslösning som kommer att användas till motionsbassängen. För att studera hur denna lösning fungerar och hur god luftväxling den skapar över vattenytan har en modell av simhallen skapats i CAD-program. Luftflöden har sedan simulerats i en förenklad CFD modellen och jämförts med ett röktest i en liknande simhall. Utöver den lösning som är tänkt att byggas har ett alternativ med kompletterande frånluftsdon i golvnivå simulerats.Resultatet indikerar att lufthastigheter över vattenytan ligger inom de rekommendationer som finns angivna. Luften har en tendens att röra sig i lokalen med ett återcirkulerande beteende där tilluften följer taket in i hallen för att sedan gå ner vid bakre väggen och tillbaka över vattenytan. Luftrörelserna följer detta beteende oberoende om frånluftsdonet är placerat i golv- eller taknivå. Någon skillnad i mängd bortfört trikloramin kan inte säkerställas med de metoder som använts i rapporten. Röktestet gav inte ett tillräckligt tydligt resultat för att några kopplingar till simulering ska kunna göras.Brist på tid, förkunskaper och erfarenhet inom området gör att osäkerheten kring de resultat som nåtts är stor. Mer arbete inom CFD och badhusventilation krävs för att öka trovärdigheten.

Abstract [en]

Public baths contributes significantly to the promotion of public health and wellbeing. To be able to supply a pleasant experience for bathers, a high quality of water and air is required. To avoid spreading of pathogens between bathers, Chlorine is used as a central component for disinfecting the water. Chlorine residues such as Trichloramine affect human health and are concentrated above the water surface and will remain in the breathing zone unless the pollution is carried away by air movement.Nolhaga public bath is undergoing a renovation and this report is a study of the new ventilation system which has been installed. To investigate the air flow pattern in the hall a CAD model of the space was created. CFD software was used to simulate airflow in the model. Results have also been compared with a smoke test, performed in a similar building. In addition to the suggested solution a different approach, with additional exhaust air vents placed at floor level, has been tested.The results show that the air speeds over the water surface are within the given recommendations. The air has a tendency to move around in the room with a recirculating behaviour where the supply air follows the roof to the back wall and then returns over the surface of the water. This kind of behaviour might be beneficial for removing Trichloramines if exhaust air vents are placed near the air supply units. This method uses the air movement to remove pollutants where the concentration is highest and removes them from the building. Performed smoke test gave only vague indications that the simulation results can be linked to actual air movement due to the small amount of information it provided.Due to the lack of time, knowledge and experience in the field, the uncertainty of the achieved results is great. Additional work in CFD and ventilation of public baths is required to enhance credibility of results.

Place, publisher, year, edition, pages
2017.
Keywords [en]
Ventilation, Air distribution, Public baths, CFD, Trichloramine
Keywords [sv]
Ventilation, Luftföring, Simhall, CFD, Trikloramin
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:hb:diva-12665OAI: oai:DiVA.org:hb-12665DiVA, id: diva2:1142978
Subject / course
Energiteknik
Supervisors
Examiners
Available from: 2017-10-13 Created: 2017-09-20 Last updated: 2019-08-27Bibliographically approved

Open Access in DiVA

fulltext(2515 kB)1529 downloads
File information
File name FULLTEXT01.pdfFile size 2515 kBChecksum SHA-512
2ede15c9c22d2f00cbac954f2e0cb61315fdac8c91a3a0b44976577de82f27f947cf4c3144feb6e18fde06977f9e73babcdb132ffcf5c441d468944bf113dad2
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1532 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 581 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf