Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-cite-them-right
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Wearable Biomedical Measurement Systems for Assessment of Mental Stress of Combatants in Real Time
Högskolan i Borås, Institutionen Ingenjörshögskolan. (Medical TexTTronics)
Högskolan i Borås, Institutionen Ingenjörshögskolan. (Medical TexTTronics)
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Sensors, ISSN 1424-8220, E-ISSN 1424-8220, Vol. 14, nr 4, s. 7120-7141Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The Spanish Ministry of Defense, through its Future Combatant program, has sought to develop technology aids with the aim of extending combatants' operational capabilities. Within this framework the ATREC project funded by the “Coincidente” program aims at analyzing diverse biometrics to assess by real time monitoring the stress levels of combatants. This project combines multidisciplinary disciplines and fields, including wearable instrumentation, textile technology, signal processing, pattern recognition and psychological analysis of the obtained information. In this work the ATREC project is described, including the different execution phases, the wearable biomedical measurement systems, the experimental setup, the biomedical signal analysis and speech processing performed. The preliminary results obtained from the data analysis collected during the first phase of the project are presented, indicating the good classification performance exhibited when using features obtained from electrocardiographic recordings and electrical bioimpedance measurements from the thorax. These results suggest that cardiac and respiration activity offer better biomarkers for assessment of stress than speech, galvanic skin response or skin temperature when recorded with wearable biomedical measurement systems.

Ort, förlag, år, upplaga, sidor
MDPI AG , 2014. Vol. 14, nr 4, s. 7120-7141
Nyckelord [en]
smart Textiles, wearable sensors, Smart Textiles
Nationell ämneskategori
Biomedicinsk laboratorievetenskap/teknologi Elektroteknik och elektronik
Forskningsämne
Textil och mode (generell)
Identifikatorer
URN: urn:nbn:se:hb:diva-2053DOI: 10.3390/s140407120Lokalt ID: 2320/14700OAI: oai:DiVA.org:hb-2053DiVA, id: diva2:870134
Tillgänglig från: 2015-11-13 Skapad: 2015-11-13 Senast uppdaterad: 2018-01-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltexthttp://www.mdpi.com/1424-8220/14/4/7120

Personposter BETA

Seoane, FernandoFerreira González, Javier

Sök vidare i DiVA

Av författaren/redaktören
Seoane, FernandoFerreira González, Javier
Av organisationen
Institutionen Ingenjörshögskolan
I samma tidskrift
Sensors
Biomedicinsk laboratorievetenskap/teknologiElektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 497 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-cite-them-right
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf