Experimental Validation of a Method for Removing the Capacitive Leakage Artifact from Electrical Bioimpedance Spectroscopy Measurements
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.
2010 (engelsk)Inngår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 21, nr 11, s. 115802-Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Often when performing electrical bioimpedance (EBI) spectroscopy measurements, the obtained EBI data present a hook-like deviation, which is most noticeable at high frequencies in the impedance plane. The deviation is due to a capacitive leakage effect caused by the presence of stray capacitances. In addition to the data deviation being remarkably noticeable at high frequencies in the phase and the reactance spectra, the measured EBI is also altered in the resistance and the modulus. If this EBI data deviation is not properly removed, it interferes with subsequent data analysis processes, especially with Cole model-based analyses. In other words, to perform any accurate analysis of the EBI spectroscopy data, the hook deviation must be properly removed. Td compensation is a method used to compensate the hook deviation present in EBI data; it consists of multiplying the obtained spectrum, Zmeas(ω), by a complex exponential in the form of exp(–jωTd). Although the method is well known and accepted, Td compensation cannot entirely correct the hook-like deviation; moreover, it lacks solid scientific grounds. In this work, the Td compensation method is revisited, and it is shown that it should not be used to correct the effect of a capacitive leakage; furthermore, a more developed approach for correcting the hook deviation caused by the capacitive leakage is proposed. The method includes a novel correcting expression and a process for selecting the proper values of expressions that are complex and frequency dependent. The correctness of the novel method is validated with the experimental data obtained from measurements from three different EBI applications. The obtained results confirm the sufficiency and feasibility of the correcting method.

sted, utgiver, år, opplag, sider
Institute of Physics Publishing Ltd. , 2010. Vol. 21, nr 11, s. 115802-
Emneord [en]
Medicinteknik
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-2985DOI: 10.1088/0957-0233/21/11/115802Lokal ID: 2320/7362OAI: oai:DiVA.org:hb-2985DiVA, id: diva2:871079
Tilgjengelig fra: 2015-11-13 Laget: 2015-11-13 Sist oppdatert: 2017-11-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Buendia, RubenSeoane Martínez, Fernando

Søk i DiVA

Av forfatter/redaktør
Buendia, RubenSeoane Martínez, Fernando
Av organisasjonen
I samme tidsskrift
Measurement science and technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 123 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf