Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-cite-them-right
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Textrode functional straps for bioimpedance measurements-experimental results for body composition analysis
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.ORCID-id: 0000-0003-4853-7731
2013 (engelsk)Inngår i: European Journal of Clinical Nutrition, ISSN 0954-3007, E-ISSN 1476-5640, Vol. 67, nr Suppl 1, s. 22-27Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background/Objectives:Functional garments for physiological sensing purposes have been used in several disciplines, that is, sports, firefighting, military and medicine. In most of the cases, textile electrodes (textrodes) embedded in the garment are used to monitor vital signs and other physiological measurements. Electrical bioimpedance (EBI) is a non-invasive and effective technology that can be used for the detection and supervision of different health conditions.EBI technology could make use of the advantages of garment integration; however, a successful implementation of EBI technology depends on the good performance of textrodes. The main drawback of textrodes is a deficient skin-electrode interface that produces a high degree of sensitivity to signal disturbances. This sensitivity can be reduced with a suitable selection of the electrode material and an intelligent and ergonomic garment design that ensures an effective skin-electrode contact area.Subjects/Methods:In this work, textrode functional straps for total right side EBI measurements for body composition are presented, and its measurement performance is compared against the use of Ag/AgCl electrodes. Shieldex sensor fabric and a tetra-polar electrode configuration using the ImpediMed spectrometer SFB7 in the frequency range of 3-500 kHz were used to obtain and analyse the impedance spectra and Cole and body composition parameters.Results:The results obtained show stable and reliable measurements; the slight differences obtained with the functional garment do not significantly affect the computation of Cole and body composition parameters.Conclusions:The use of a larger sensor area, a high conductive material and an appropriate design can compensate, to some degree, for the charge transfer deficiency of the skin-electrode interface.

sted, utgiver, år, opplag, sider
Nature Publishing Group , 2013. Vol. 67, nr Suppl 1, s. 22-27
Emneord [en]
textile sensors, textrodes, body composition, textile electrodes, bioimpedance spectroscopy, wrist-to-ankle measurement, Medicinteknik
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-1495DOI: 10.1038/ejcn.2012.161ISI: 000318689500005PubMedID: 23299868Lokal ID: 2320/11996OAI: oai:DiVA.org:hb-1495DiVA, id: diva2:869552
Tilgjengelig fra: 2015-11-13 Laget: 2015-11-13 Sist oppdatert: 2017-11-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Márquez, Juan CarlosSeoane, FernandoLindecrantz, Kaj

Søk i DiVA

Av forfatter/redaktør
Márquez, Juan CarlosSeoane, FernandoLindecrantz, Kaj
Av organisasjonen
I samme tidsskrift
European Journal of Clinical Nutrition

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 345 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • harvard-cite-them-right
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf