Influence of electrode mismatch on Cole parameter estimation from Total Right Side Electrical Bioimpedance Spectroscopy measurements
Högskolan i Borås, Institutionen Ingenjörshögskolan.
Högskolan i Borås, Institutionen Ingenjörshögskolan.
2012 (engelsk)Inngår i: Medical Engineering and Physics, ISSN 1350-4533, E-ISSN 1873-4030, Vol. 34, nr 7, s. 1024-1028Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Applications based on measurements of Electrical Bioimpedance (EBI) spectroscopy analysis, like assessment of body composition, have proliferated in the past years. Currently Body Composition Assessment (BCA) based in Bioimpedance Spectroscopy (BIS) analysis relays on an accurate estimation of the Cole parameters R0 and R∞. A recent study by Bogonez-Franco et al. has proposed electrode mismatch as source of remarkable artefacts in BIS measurements. Using Total Right Side BIS measurements from the aforementioned study, this work has focused on the influence of electrode mismatch on the estimation of R0 and R∞ using the Non-Linear Least Square curve fitting technique on the modulus of the impedance. The results show that electrode mismatch on the voltage sensing electrodes produces an overestimation of the impedance spectrum leading to a wrong estimation of the parameters R0 and R∞, and consequently obtaining values around 4% larger that the values obtained from BIS without electrode mismatch. The specific key factors behind electrode mismatch or its influence on the analysis of single and spectroscopy measurements have not been investigated yet, no compensation or correction technique is available to overcome the deviation produced on the EBI measurement. Since textile-enabled EBI applications using dry textrodes, i.e. textile electrodes with dry skin–electrode interfaces and potentially large values of electrode polarization impedance are more prone to produce electrode mismatch, the lack of a correction or compensation technique might hinder the proliferation of textile-enabled EBI applications for personalized healthcare monitoring.

sted, utgiver, år, opplag, sider
Elsevier Ltd , 2012. Vol. 34, nr 7, s. 1024-1028
Emneord [en]
Physiological measurements, Bioimpedance, Medicinteknik
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-1408DOI: 10.1016/j.medengphy.2012.05.011ISI: 000308387600027PubMedID: 22738873Lokal ID: 2320/11711OAI: oai:DiVA.org:hb-1408DiVA, id: diva2:869463
Tilgjengelig fra: 2015-11-13 Laget: 2015-11-13 Sist oppdatert: 2017-11-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Buendía, RubénSeoane, Fernando

Søk i DiVA

Av forfatter/redaktør
Buendía, RubénSeoane, Fernando
Av organisasjonen
I samme tidsskrift
Medical Engineering and Physics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 235 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf