Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fukttillstånd i olika ytterväggar med tre olika fasadsystem: En parameterstudie med Wufi
Högskolan i Borås, Akademin för textil, teknik och ekonomi.
Högskolan i Borås, Akademin för textil, teknik och ekonomi.
2015 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Moisture conditions in different exterior walls with three different façade systems : A parameter study with Wufi (engelsk)
Abstract [sv]

Ett stort antal av miljonprogrammets byggnader är idag i behov av renovering. Då många av dessa byggnader har en hög energiförbrukning kan det vara lönsamt att samtidigt energieffektivisera byggnaderna, bland annat genom tilläggsisolering. Det är av stor vikt att noggrant undersöka hur byggnaderna påverkas ur fukthänsyn innan nya fasadsystem tas i bruk för att undvika framtida fuktrelaterade skador.Syftet är att undersöka tre fasadsystem utifrån hur olika fuktbelastningar, väderstreck, tilläggsisoleringar och stommaterial påverkar ytterväggars fukttillstånd och risken för mikrobiell tillväxt. Även hur väl de olika fasadsystemen lämpar sig för att uppföras på en befintlig stomme i trä-, lättbetong- och betongstomme har undersökts. För att undersöka detta har fuktsimuleringar gjorts i fuktberäkningsprogrammet Wufi och resultaten har analyserats genom jämförelse av RF-kurvor samt riskbedömning för mögeltillväxt i Wufi Bio.En övergripande slutsats är bland annat att inläckage av slagregn är en stor belastning för fasadsystemen. Systemens fuktsäkerhet beror till stor del på dess förmåga att hantera inläckaget.Studien visar även att en fungerande ventilerad luftspalt, en god dränerande funktion eller en konstruktion med genomgående relativt ångöppna material har förmågan att hantera inläckage av slagregn effektivt.

Abstract [en]

A large number of buildings built under “miljonprogrammet” is today in need of renovation. With their high energy consumption it is also considered profitable to improve the buildings energy efficiency e.g. by additional insulation. It is however important to thoroughly evaluate potential damp issues that might arise as a result of these improvements before starting to implement a new building exterior.The aim of this study was to investigate three different façade systems based on how their moisture content and risk for mould growth are affected by different moisture loads, orientation, and additional insulation. Included is also a performance evaluation for each building exterior solution mounted on existing structure of wood, lightweight concrete and concrete structure. Damp simulations were done with the program Wufi and the results were then analysed by comparison to RF-curves in combination with risk assessments of the growth of mould with “Wufi Bio”.The overall conclusion shows that leakage due to torrential rain poses a great strain on building exterior systems. A solutions damp proof quality is largely dependent on its ability to withstand leakage from outer sources.The study also shows that a well ventilated cavity wall, sufficient drainage or a construction of exclusively vapour open materials has a positive impact on the amount of leakage.

sted, utgiver, år, opplag, sider
2015. , s. 75
Emneord [en]
Innovative façade system, Wufi 1D, Wufi 2D, Wufi Bio, driving rain, parameter study, additional insulation.
Emneord [sv]
Innovativa fasadsystem, Wufi 1D, Wufi 2D, Wufi Bio, slagregn, parameterstudie, tilläggsisolering.
HSV kategori
Identifikatorer
URN: urn:nbn:se:hb:diva-708OAI: oai:DiVA.org:hb-708DiVA, id: diva2:852933
Fag / kurs
Byggteknik
Uppsök
Technology
Tilgjengelig fra: 2015-09-25 Laget: 2015-09-10 Sist oppdatert: 2015-09-25bibliografisk kontrollert

Open Access i DiVA

fulltext(4489 kB)840 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4489 kBChecksum SHA-512
924ea51892562414eca763608cdb9aca03f7fd5b6a307ca3d05c4094e36bc8b65073f3cb63bd528195935308ab02e48fe0676595149ccc7312c7abac2f3d30ea
Type fulltextMimetype application/pdf
bilaga(9057 kB)85 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 9057 kBChecksum SHA-512
c263063aabbd566b707c76ba3cbcde750de7a0752af90a0fec5837287a156cddfbf1349ddb9a4f0dac6ad0d8f8b38354ac51b2d5611e916262d6f71d5e716d78
Type attachmentMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 925 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1084 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • harvard-cite-them-right
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf